TM 5-3895-373-20
E.
INSTALL Continued.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after
skin
contact.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
h.
Apply hydraulic fitting sealant to threads of elbow
(33).
i.
Connect hose (32) to elbow (33).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
j. Install lead wire (30) and terminal nut (29) onto glow
plug (31). Tighten terminal nut. Apply electrical insulating
varnish to glow plug terminal.
k. Use tie wraps as necessary to secure wiring and
hoses away from the burner chamber assembly.
GO TO NEXT PAGE
14-43