TM 5-3895-373-20A.REMOVE.1.REMOVE FILLER ASSEMBLY.Cleaning solvent, P-D-680, is TOXICand flammable. Wear protectivegoggles and gloves. Use only in awell ventilated area. Avoid contactwith skin, eyes, and clothes, and donot breathe vapors. Keep away fromheat or flame. Never smoke whenusing solvent; the flashpoint for Typem cleaning solvent is 200°F (93,3°C).Failure to do so may result in injuryor death to personnel.If personnel become dizzy whileusing cleaning solvent, immediatelyget fresh air and medical help. Ifsolvent contacts skin or clothes,flush with cold water. If solventcontacts eyes, flush eyes with waterand get immediate medical attention.Cleanliness is extremely importantwhen working around an openhydraulic system. Ensure that thearea around the filler assembly isclean and free of debris prior toremoval. Failure to do so couldcontaminate the hydraulic systemand cause component damage.a.Clean exposed surfaces of filler assembly andsurrounding area with a clean lint-free clothsoaked in cleaning solvent. Dry area with aclean lint-free cloth.GO TO NEXT PAGE13-43