TM 5-3895-373-20
13.7.
REPAIR HYDRAULIC RESERVOIR - Continued.
B.
INSTALL.
1.
INSTALL FILLER ASSEMBLY.
a.
With mounting holes lined up, install gasket (7),
strainer (6), gasket (5), and filler neck (4).
Do not use metric machine screws
that come with new filler assembly.
Reuse machine screws removed from
reservoir or obtain correct screws
from supply system.
b.
Discard metric screws supplied with new filler
assembly.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush eyes with water and get
immediate medical attention.
c.
Use a cleaning cloth soaked in thread locking
compound solvent to clean the threads of
machine screws (2).
d.
Install lockwashers (3) onto machine screws (2).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
e.
Apply thread locking compound to machine
screws (2).
f.
Install machine screws (2). Evenly tighten
machine screws.
g.
Install hydraulic reservoir cap (1).
GO TO NEXT PAGE
13-46