TM 5-3895-373-20A. REMOVE.1.DISCONNECT HOSES.WARNINGCleaning solvent, P-D-680, is TOXICand flammable. Wear protectivegoggles and gloves. Use only in awell ventilated area. Avoid contactwith skin, eyes, and clothes, and donot breathe vapors. Keep away fromheat or flame. Never smoke whenusing solvent; the flashpoint for TypeIII cleaning solvent is 200°F (93,3°C).Failure to do so may result in injuryor death to personnel.If personnel become dizzy whileusing cleaning solvent, immediatelyget fresh air and medical help. Ifsolvent contacts skin or clothes,flush with cold water. If solventcontacts eyes, flush eyes with waterand get immediate medical attention.CAUTIONThoroughly clean hydraulic hosesand fittings before disconnecting.Always plug or cap off disconnectedfittings to prevent intrusion ofcontaminates. Failure to properlyclean and cap off connectors mayresult in hydraulic systemcontaminationand equipmentdamage.a.Use cleaning solvent and cleaning cloth toclean around hydraulic hose (1 and 2)fittings on tow point cylinder (3).b.Tag hydraulic hoses (1 and 2) to ensureinstallation in the same location duringinstallation of tow point cylinder.GO TO NEXT PAGE13-3