A. REMOVE.
1.
RELIEVE PRESSURE FROM ACCUMULATOR.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
m cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Use parts cleaning brush and cleaning
solvent to clean all dust, dirt, and oil or
grease residue from hydraulic fittings at
accumulator (1).
b.
Place drip pan below accumulator (1)
under hose (2).
WARNING
Accumulator/adapter
connection
must be shielded and hydraulic
pressure slowly bled off before
removing adapter. If line pressure is
not allowed to bleed off, adapter
connection will emit a high energy
spray when opened. Failure to shield
connection and slowly bleed off
hydraulic pressure may result in
serious injuries to personnel.
c.
Cover accumulator (1) and hose (2) with a
2 in. (51 mm) mat of protective cleaning
cloths.
GO TO NEXT PAGE
9-3