TM 5-3895-373-20A.REMOVE - Continued.2.REMOVE ACCUMULATOR AND FITTINGS.a.While holding accumulator (1), loosenhose clamps (7).b.Remove accumulator (1) and cushioningpad (8).c.Secure accumulator (1) with wrenchacross hex flats. Unscrew straight adapter(9) with attached cross (10), elbows (5),straight adapter (6), and pipe nipple (11).WARNINGHydraulic oil can be moderatelyflammable and can be an irritant tothe skin, eyes, and respiratorysystem. Avoid prolonged exposure.Eye protection and rubber glovesmust be worn when working withhydraulic oil.d.Drain hydraulic oil from accumulator (1)into drip pan. Dispose of hydraulic oil inaccordance with local procedures.e.Remove and discard preformed packing(12).NOTEPerform the following removalprocedures only as needed to replacedamaged or faulty components.f.Remove elbows (5) and/or straight adapter(6) and pipe nipple (11) from cross (10).g.Remove pipe nipple (11) from straightadapter (9).GO TO NEXT PAGE9-5