TM 5-3895-373-20
8.3.
REPLACE HYDRAULIC CHARGE FILTER ASSEMBLY-continued.
C. INSTALL.
1.
INSTALL ADAPTERS ONTO FILTER INSTALL
FILTER HEAD.
WARNING
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the skin, eyes and respiratory system.
Avoid
prolonged
exposure
Eye
protection and rubber gloves must be
worn when working with hydraulic
oil.
CAUTION
Be careful not to damage preformed
packing when sliding over threads.
Sharp edges of threads can cut or
damage
preformed
packing.
Damaged
preformed
packing
will
cause leakage affect performance.
a.
Coat preformed packings (16 and 17) with
hydraulic oil and install onto preformed
packing end of adapters (14 and 15).
b.
Position filter head (13) so the flow
indicating arrow is to your left. Install
adapters onto filter head and position so
that hose ends of adapters are down and
facing toward you at a 450 angle.
WARNING
Thread locking compound can cause
eye
damage
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Install lockwasher (12) on bolts (11). Apply
thread locking compound to threads of
bolts.
d.
Install filter head (13) with flow direction
arrow pointing toward front of machine and
on your left hand side. Secure filter head
with bolts (11). Tighten bolts to 11 lb-ft
(15Nom).
e.
Tighten adapter locking nuts.
WARNING
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wash
after skin contact. Wear safety
goggles/glasses when using. Avoid
contact with eyes or skin. If sealant
contacts eyes, flush eyes with water
and get immediate medical attention.
f.
Apply hydraulic fitting sealant to threads of
adapters (14 and 15).
g.
Remove plugs from hoses. Connect
hydraulic hoses (9 and 10) to adapters (14
and 15).
h.
Do not overtighten hoses.
GO TO NEXT PAGE
8-14