TM 5-3895-373-209.2.REPLACE TRACK TENSIONING ACCUMULATOR - Continued.A.REMOVE - Continued.WARNINGHydraulic oil can be moderately flammable andcan be an irritant to the skin, eyes, andrespiratory system. Avoid prolonged exposure.Eye protection and rubber gloves must be wornwhen working with hydraulic oil.d.Carefully crack open hose (2) and wait forhydraulic oil to start dripping. Do notremove hose.e.Allow 15 minutes for all hydraulic pressureto bleed off, then open hose (2) a littlemore. After all hydraulic pressure isrelieved, disconnect hose.f.Disconnect hoses (3 and 4).g.Use a cleaning cloth to wipe hydraulicfitting sealant residue from elbows (5) andstraight adapter (6).h.Plug hoses (2, 3, and 4) and cap elbows(5) and straight adapter (6).GO TO NEXT PAGE9-4