TM 5-3895-373-20
A.
REMOVE - Continued.
4.
REMOVE FILTER HEAD.
a.
Disconnect hydraulic hoses (9 and 10).
Plug hose ends to prevent contamination.
b.
Loosen adapter locking nuts.
c.
Remove bolts (11), lockwashers (12), and
filter head (13). Discard lockwashers.
d.
Remove adapters (14 and 15). Remove
and discard preformed packings (16 and
17).
B.
CLEAN.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves Use only in a well
ventilated area. Avoid contact with
skin, eyes, and clothes, and do not
breathe vapors. Keep away from heat
or flame. Never smoke when using
solvent; the flashpoint for Type HI
cleaning solvent is 200°F (93,30C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
CLEAN HYDRAULIC CHARGE FILTER PARTS.
a.
Use cleaning solvent and a lint-free cloth
to clean out inside of filter bowl. Wipe dry
with a clean lint-free cloth.
b.
Use cleaning solvent and a lint -free cloth
to wipe off filter end surface and clogging
indicator area of filter head.
c.
Let dry completely before reassembling.
2.
CLEAN BOLT AND ADAPTER THREADS.
WARNING
Thread locking compound solvent
can cause eye damage. Wear safety
goggles./glasses when using. Avoid
contact with eyes. If solvent contacts
eyes, flush with water and get
immediate medical attention.
a.
Use thread locking compound solvent to
clean threads of bolts.
b.
Dry with a cleaning cloth.
c.
Use cleaning cloth to wipe residue from
threads of adapters.
GO TO NEXT PAGE
8-13