TM 5-3895-373-20B.INSTALL Continued.2.INSTALL HORN.NOTEInstall horn at an angle to keeprainwater from entering.a.Install horn (10), ground wire (12), flat washer(11), and bolt (9).b.Install self-locking hex nut (8). Tighten nut to 19lb-ft (26 N•m).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.c.Apply electrical insulating varnish to ground wire(12) connection.Adhesive is TOXIC and extremelyflammable. Keep away from heat,sparks, and open flames. Use only inwell ventilated areas. Do not breathevapors or swallow and avoid contactwith eyes and skin. Failure to do somay result in injury or death topersonnel.If personnel become dizzy whileusing adhesive, immediately get freshair and medical attention. Ifpersonnel swallow adhesive, do notinduce vomiting. Get immediatemedical attention. If adhesivecontacts eyes, flush eyes with waterfor 15 minutes and get immediatemedical attention. If adhesivecontacts skin, wash thoroughly withsoap and water.d.Apply adhesive to back of sound foam (7) andplace over self-locking hex nut (8).GO TO NEXT PAGE7-137