TM 5-3895-373-207.11.REPLACE/REPAIR VOLTAGE TRANSFORMER - Continued.A. DISCONNECT.When disconnecting batteries,disconnect negative battery cablebefore disconnecting positive batterycable. Failure to disconnect batteriesin the proper sequence may lead toelectrical shock or short circuit andresult in severe personnel injury.1.UNBUCKLE BATTERY BOX HOLDDOWNSTRAPS (1) AND REMOVE BATTERY BOXCOVERS (2).2.LIFT RUBBER BATTERY TERMINAL CAPS (3)FROM BATTERY TERMINALS.3.REMOVE BATTERY NUT (4) AND NEGATIVEBATTERY CABLE (5) FROM OUTBOARDBATTERY.4. REMOVE BATTERY NUT (4) AND POSITIVEBATTERY CABLE (6) FROM INBOARDBATTERY.GO TO NEXT PAGE7-94