TM 5-3895-373-20
7.10.
REPLACE/REPAIR RELAY AND CIRCUIT BREAKER ASSEMBLY - Continued.
B.
ASSEMBLE - Continued.
e.
Apply
electrical
insulating
compound
to
relay/circuit breaker holder (2), circuit breakers
(1), and relays (3).
NOTE
Relays are all alike and are interchangeable
on relay panel.
f.
Install relays (3) into relay/circuit breaker holder
(2).
NOTE
Circuit breakers CBI through CB8 are alike
and CB9 through CB 11 are alike.
g.
Refer to table below and illustration and install
circuit breakers (1) into relay/circuit breaker
holder (2).
CIRCUIT
VALUE
BREAKER
(AMPS)
CB1
15
CB2
20
CB3
20
CB4
10
CB5
15
CB6
10
CB8
15
CB9
15
CB01
15
CB11
15
NOTE
FOLLOW-ON-TASK:
Install relay and circuit breaker assembly per paragraph 7.6.
END OF TASK
7-92