7.2.
REPLACE ALTERNATOR - Continued.
B.
INSTALL - Continued.
4.
RECONNECT ALTERNATOR WIRING.
a.
Apply
electrical
insulating
compound
to
alternator W terminal.
b.
Reconnect tachometer sensor wire 102 (7) to
alternator W terminal.
c.
Reconnect DCA wire 329 (11) and alternator
output wire 160 (10) to alternator B+ terminal.
d.
Install lockwasher (9) and hex nut (8) on
alternator B+ terminal. Tighten hex nut.
e.
Reconnect alternator excitation wire 328 (14) to
alternator D+ terminal.
f.
Install lockwasher (13) and hex nut (12) to
alternator D+ terminal. Tighten hex nut.
Electrical insulating varnish fumes
can be harmful if inhaled. Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
g.
Apply electrical insulating varnish to all alternator
electrical terminals.
GO TO NEXT PAGE