TM 5-3895-373-20
A.
REMOVE - Continued.
2.
PLACE MACHINERY WIPING TOWEL UNDER
FILTER BOWL (2)
WARNING
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
3.
REMOVE FILTER BOWL (2). POUR WASTE
OIL INTO DRIP PAN. DISPOSE OF WASTE
OIL
IN
ACCORDANCE
WITH
LOCAL
PROCEDURES.
4.
REMOVE
FILTER
ELEMENT
(3)
FROM
FILTER HEAD (4). DISPOSE OF FILTER
ELEMENT, WASTE HYDRAULIC OIL, AND
CONTAMINATED
MACHINERY
WIPING
TOWELS IN ACCORDANCE WITH LOCAL
PROCEDURES.
CAUTION
Use caution when removing o-rings.
Scratched or dented seal grooves can
cause bypass leakage. Do not use
excessive force when removing o-
rings. Use an o-ring tool to remove o-
rings.
5.
USE AN O-RING TOOL AND REMOVE O-
RINGS (5 AND 6) FROM FILTER BOWL (2).
DISCARD O-RINGS.
GO TO NEXT PAGE
2-423