TM 5-3895-373-20
A.
REMOVE - Continued.
WARNING
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
2.
PLACE A DRIP PAN UNDER HYDRAULIC
RETURN FILTER ASSEMBLY.
3.
USE AN OIL FILTER REMOVAL TOOL TO
REMOVE HYDRAULIC RETURN FILTER
ELEMENT
(2).
DISCARD
HYDRAULIC
RETURN
FLUID
FILTER
ELEMENT
AND
EXCESS HYDRAULIC OIL IN ACCORDANCE
WITH LOCAL PROCEDURES.
CAUTION
Use caution when removing seals
and preformed packings. Scratched
or dented seal grooves can cause
bypass
leakage.
Do
not
use
excessive force when removing seals
and preformed packings. Use an o-
ring
tool
to
remove
seals
and
preformed packings.
4.
USE AN O-RING TOOL, AND REMOVE AND
DISCARD GASKET (3).
B.
INSTALL.
WARNING
Cleaning solvent, P-D-680, is TOXIC
and flammable. Wear protective
goggles and gloves. Use only in a
well ventilated area. Avoid contact
with skin, eyes, and clothes, and do
not breathe vapors. Keep away from
heat or flame. Never smoke when
using solvent; the flashpoint for Type
Im cleaning solvent is 200°F (93,3°C).
Failure to do so may result in injury
or death to personnel.
If personnel become dizzy while
using cleaning solvent, immediately
get fresh air and medical help. If
solvent contacts skin or clothes,
flush with cold water. If solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
1.
USE CLEANING SOLVENT AND LINT-FREE
CLOTH TO CLEAN HYDRAULIC RETURN
FILTER HEAD (4).
GO TO NEXT PAGE
2-427