TM 5-3895-373-20B. INSTALL.1.USE CLEAN, LINT-FREE CLOTH TO WIPETHREADS OF DRAIN PLUG (2) CLEAN.WARNINGHydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.2.APPLY HYDRAULIC FITTING SEALANT TOTHREADS OF DRAIN PLUG (2). INSTALLDRAIN PLUG INTO RESERVOIR HOSE (1)AND TIGHTEN.NOTEFOLLOW-ON-TASKS:Remove cribbing and lower paving machine per paragraph 2.24.2.Install right access cover per TM 5-3895-373-10. Close right accessdoor per TM 5-3895-373-10. Add hydraulic oil per TM 5-3895-373-10.END OF TASK2-421