TM 5-3895-373-202.23.9. REPLACE HYDRAULIC CHARGE FILTER ELEMENT - Continued.B. INSTALL.WARNINGCleaning solvent, P-D-680, is TOXICand flammable. Wear protectivegoggles and gloves. Use only in awell ventilated area. Avoid contactwith skin, eyes, and clothes, and donot breathe vapors. Keep away fromheat or flame. Never smoke whenusing solvent; the flashpoint for TypeHI cleaning solvent is 200°F (93,3°C).Failure to do so may result in injuryor death to personnel.If personnel become dizzy whileusing cleaning solvent, immediatelyget fresh air and medical help. Ifsolvent contacts skin or clothes,flush with cold water. If solventcontacts eyes, flush eyes with waterand get immediate medical attention.1.CLEAN INSIDE OF FILTER BOWL (2) ANDFILTER HEAD (4) USING CLEANINGSOLVENT AND LINT-FREE CLOTH.WARNINGHydraulic oil can be moderatelyflammable and can be an irritant tothe skin, eyes, and respiratorysystem. Avoid prolonged exposure.Eye protection and rubber glovesmust be worn when working withhydraulic oil.2.COAT O-RING (7) WITH CLEAN HYDRAULICOIL.3.INSTALL FILTER ELEMENT (3) ONTO FILTERHEAD (4).4.COAT O-RINGS (5 AND 6) WITH CLEANHYDRAULIC OIL. INSTALL O-RINGS ONTOFILTER BOWL (2).GO TO NEXT PAGE2-424