TM 5-3895-373-20
B.
INSTALL - Continued.
2.
INSTALL
ENDGATE
HAND
LEVER
ASSEMBLY.
Thread locking compound solvent
can cause eye damage. Wear safety
goggles/glasses when using. Avoid
contact
with
eyes.
If
solvent
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Clean threads of hex head cap screws (3) with
thread locking compound solvent.
b.
Install lockwashers (4) onto hex head cap
screws (3).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
c.
Apply thread locking compound to threads of
hex head cap screws (3).
d.
Install hand lever assembly (1) onto endgate
support arm (5) using lockwashers (4) and hex
head cap screws (3). Tighten cap screws to 37
lb-ft (50 Nm).
e.
Hook chain (2) to hand lever assembly (1).
END OF TASK
15-115