TM 5-3895-373-2015.4.REPLACE/REPAIR CROWN ADJUSTMENT ASSEMBLY - Continued.A. REMOVE.1.DISCONNECT HYDRAULIC HOSES.Hydraulic oil can be moderatelyflammable and can be an irritant tothe skin, eyes, and respiratorysystem. Avoid prolonged exposure.Eye protection and rubber glovesmust be worn when working withhydraulic oil.Thoroughly clean hoses and fittingsbefore disconnecting. Always plugor cap off disconnected fittings toprevent intrusion of contaminants.Failure to properly clean and cap offconnectors may result in systemcontaminationand equipmentdamage.a.Place machinery wiping towels around fittings ofhydraulic hoses (I through 4).b.Wipe all dirt and dust from fittings of hydraulichoses (I through 4) with cleaning cloths.c.Tag and disconnect hydraulic hoses (1 through4) from straight adapters (5 through 8). Drain oilfrom hoses into a utility pail.d.Plug hydraulic hoses (1 through 4) and capstraight adapters (5 through 8).e.Dispose of saturated machinery wiping towelsand waste hydraulic oil in accordance withlocal procedures.GO TO NEXT PAGE15-32