TM 5-3895-373-20E. INSTALL Continued.Hydraulic fitting sealant can causeeye damage or skin irritation. Washafter skin contact. Wear safetygoggles/glasses when using. Avoidcontact with eyes or skin. If sealantcontacts eyes, flush eyes with waterand get immediate medical attention.m.Apply hydraulic fitting sealant to threads of elbow(9).n.Connect hose (8) to elbow (9).Electrical insulating varnish fumescan be harmful if inhaled. Use only ina well ventilated area. Avoidprolonged exposure to fumes. Ifpersonnel become dizzy or drowsyduring use, get immediate medicalattention.o.Install lead wire (6) and terminal nut (5) ontoglow plug (7). Tighten terminal nut. Applyelectrical insulating varnish to glow plug terminal.p.Use tie wraps as necessary to secure wiring andhoses away from the burner chamber assembly.GO TO NEXT PAGE14-47