TM 5-3895-385-23-2
0395
NATO Slave Receptacle Removal -- Continued.
NOTE
The four screws securing the mounting bracket and NATO slave receptacle to the hydraulic cover
vent cannot be removed from the mounting holes in the mounting bracket.
5. Remove four nuts (Figure 3, Item 1), lock washers (Figure 3, Item 2), gasket (Figure 3, Item 3), NATO slave
receptacle (Figure 3, Item 5), receptacle mounting bracket (Figure 3, Item 6), and four screws (Figure 3, Item
7) along with protective cap (Figure 3, Item 8) and tether (Figure 3, Item 9) from hydraulic cover vent (Figure
3, Item 4). Discard lock washers.
END OF TASK
NATO Slave Receptacle Installation
1. Install NATO slave receptacle (Figure 3, Item 5), receptacle mounting bracket (Figure 3, Item 6), four screws
(Figure 3, Item 7) along with protective cap (Figure 3, Item 8) and tether (Figure 3, Item 9), gasket (Figure 3,
Item 3), four new lock washers (Figure 3, Item 2) and nuts (Figure 3, Item 1) onto hydraulic cover vent (Figure
3, Item 4).