TM 5-3895-385-23-2
0395
NATO Slave Receptacle Installation -- Continued.
NOTE
Positive (+) and negative (-) symbols are stamped on the respective NATO slave receptacle
terminals.
2. Remove electrical tape and any residue from cable ends.
3. Install positive (+) cable (Figure 4, Item 2), bolt (Figure 4, Item 4), and new lock washer (Figure 4, Item 3)
onto positive (+) terminal (Figure 4, Item 5) of NATO slave receptacle on hydraulic cover vent (Figure 4 Item
1).
4. Install negative (-) cable (Figure 4, Item 7), bolt (Figure 4, Item 9), and new lock washer (Figure 4, Item 8)
onto negative (-) terminal (Figure 4, Item 6) of NATO slave receptacle on hydraulic cover vent (Figure 4 Item
1).
0395-9