TM 5-3895-385-23-2
0279
Spraydown Pump Filter Screen Installation
Install new filter screen (Figure 2, Item 3), new gasket (Figure 2, Item 2) and strainer bottom (Figure 2, Item 4)
onto strainer top (Figure 2, Item 1).
END OF TASK
FOLLOW-ON TASK
1. Set BATTERY DISCONNECT switch to ON (TM 5-3895-385-10).
2. Verify proper operation.
3. Dispose of cleaner solution and wiping rags In Accordance With (IAW) local Standard Operating Procedure
(SOP).
END OF TASK