TM 5-3895-385-23-2
0279
Spraydown Pump Removal -- Continued.
CAUTION
Tag and label cleaner hoses prior to removal. Cleaner hoses must be installed correctly for
proper operation. Failure to comply may cause damage to equipment.
1. Disconnect two cleaner hoses (Figure 1, Items 8 and 9) from Tee (Figure 1, Item 14), and cap/plug cleaner
hoses and connection points on spraydown pump.
2. Disconnect cleaner hose (Figure 1, Item 19) from shut-off valve (Figure 1, Item 18), and cap/plug cleaner
hoses and shut-off valve.
3. Remove two nuts (Figure 1, Item 21), lock washers (Figure 1, Item 22), flat washers (Figure 1, Item 23), and
mounting bracket (Figure 1, Item 7) from studs (Figure 1, Item 24). Discard lock washers.
4. Remove screw (Figure 1, Item 10) and cover (Figure 1, Item 11) from spraydown pump (Figure 1, Item 20).
5. Disconnect cable (Figure 1, Item 13) from connector (Figure 1, Item 12).
6. Remove bolt (Figure 1, Item 1), ground wire (Figure 1, Item 2), two flat washers (Figure 1, Items 3 and 4), lock
washers (Figure 1, Item 5), nut (Figure 1, Item 6), and mounting bracket (Figure 1, Item 7) from spraydown
pump (Figure 1, Item 20). Discard lock washers.
7. Remove shut-off valve (Figure 1, Item 18), reducer (Figure 1, Item 17), filter housing (Figure 1, Item 16),
reducer (Figure 1, Item 15), and Tee fitting (Figure 1, Item 14) from spraydown pump (Figure 1, Item 20).
END OF TASK
Spraydown Pump Installation
1. Install shut-off valve (Figure 1, Item 18), reducer (Figure 1, Item 17), filter housing (Figure 1, Item 16), reducer
(Figure 1, Item 15), and Tee fitting (Figure 1, Item 14) onto spraydown pump (Figure 1, Item 20).
2. Install mounting bracket (Figure 1, Item 7), bolt (Figure 1, Item 1), ground wire (Figure 1, Item 2), two flat
washers (Figure 1, Items 3 and 4), new lock washers (Figure 1, Item 5), and nut (Figure 1, Item 6) onto
spraydown pump (Figure 1, Item 20).
3. Connect cable (Figure 1, Item 13) onto connector (Figure 1, Item 12).
4. Install screw (Figure 1, Item 10) and cover (Figure 1, Item 11) onto spraydown pump (Figure 1, Item 20).
5. Install mounting bracket (Figure 1, Item 7), two nuts (Figure 1, Item 21), new lock washers (Figure 1, Item 22),
and flat washers (Figure 1, Item 23) onto studs (Figure 1, Item 24).
6. Connect cleaner hose (Figure 1, Item 19) onto shut-off valve (Figure 1, Item 18).
7. Connect two cleaner hoses (Figure 1, Items 8 and 9) onto Tee fitting (Figure 1, Item 14).
END OF TASK