TM 5-3895-385-23-1
0214
Table 1. Electric Generator Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Attach hydraulic pressure tester
(WP 0442, Vol 3) to hydraulic
pressure test port on the main
hydraulic manifold (WP 0449,
Vol 3, Figure 3).
3. Start BMPM engine (TM 5-3895-
385-10).
4. Check hydraulic pressure at
1. If hydraulic pressure reads a
hydraulic pressure test port on
minimum of 1800 pounds per
the main hydraulic manifold
square inch (psi) (12,410
while pressing auger raise key
kiloPascals (kPa)), turn keyless
on pedestal top (TM 5-3895-385-
engine switch to the OFF
10).
position (TM 5-3895-385-10),
and proceed to next
malfunction.
2. If pressure reads below 1800 psi
(12,410 kPa), turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
1. Attempt manual override test of
1. If electric generator starts
electric generator hydraulic
spinning, turn keyless engine
switch to the OFF position (TM
5-3895-385-10), and proceed to
test 6.
start spinning, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next test.
2. Attach hydraulic pressure tester
(WP 0442 Vol 3) to hydraulic
pressure at hydraulic fitting GE
on the main hydraulic manifold
(WP 0441, Vol 3, Figure 3).
3. Start BMPM engine (TM 5-3895-
385-10).
4. Turn on screed heater box (TM
5-3895-385-10).
0214-3