• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Fuse Box Malfunction Troubleshooting Procedures -- Continued
ELECTRIC GENERATOR MALFUNCTION

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  1048    1049    1050    1051    1052  1053  1054    1055    1056    1057    1058  
img
TM 5-3895-385-23-1
0213
Table 1. Fuse Box Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure voltage (WP 0443, Vol
1. If voltage reads between 10 and
3) at battery.
13 VDC across each battery,
proceed to next malfunction.
2. If voltage reads outside of 10
and 13 VDC across each
battery, charge or replace
batteries (WP 0357, Vol 2).
7. BATTERY DISCONNECT switch
1. Ensure BATTERY
malfunction.
DISCONNECT switch is in the
ON position (TM 5-3895-385-
10).
2. Measure for continuity (WP
1. If continuity is present, replace
0443, Vol 3) across post 1 and 2
battery cable (WP 0357, Vol 2).
on the BATTERY DISCONNECT
switch (WP 0447, Vol 3, Figure
23).
2. If no continuity is present,
replace BATTERY
DISCONNECT switch (WP
0398, Vol 2).
END OF WORK PACKAGE