TM 5-3895-385-23-1
0213
Table 1. Fuse Box Malfunction Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. Measure voltage (WP 0443, Vol
1. If voltage reads between 10 and
3) at battery.
13 VDC across each battery,
proceed to next malfunction.
2. If voltage reads outside of 10
and 13 VDC across each
battery, charge or replace
batteries (WP 0357, Vol 2).
7. BATTERY DISCONNECT switch
1. Ensure BATTERY
malfunction.
DISCONNECT switch is in the
ON position (TM 5-3895-385-
10).
0443, Vol 3) across post 1 and 2
battery cable (WP 0357, Vol 2).
on the BATTERY DISCONNECT
switch (WP 0447, Vol 3, Figure
23).
2. If no continuity is present,
replace BATTERY
DISCONNECT switch (WP
0398, Vol 2).
END OF WORK PACKAGE
0213-4