• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Electric Generator Malfunction Troubleshooting Procedures -- Continued
Table 1. Left Track Fails To Move Forward Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  1054    1055    1056    1057    1058  1059  1060    1061    1062    1063    1064  
img
. . . . . . . . . . . . . .
TM 5-3895-385-23-1
0215
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT TRACK FAILS TO MOVE FORWARD
INITIAL SETUP:
Test Equipment
References -- Continued
Hydraulic test kit (WP 0440, Vol 3, Item 59)
WP 0197
Suitable lifting device (1000 lb (454 kg) minimum)
WP 0199
Web sling (WP 0440, Vol 3, Item 66)
WP 0302, Vol 2
Personnel Required
WP 0315, Vol 2
91L
WP 0420, Vol 2
Assistant
WP 0421, Vol 2
References
WP 0442, Vol 3
WP 0109
WP 0449, Vol 3
WP 0150
Equipment Conditions
WP 0171
Engine off (TM 5-3895-385-10)
WP 0180
Hydraulic oil cool (TM 5-3895-385-10)
WP 0193
WP 0195
TROUBLESHOOTING PROCEDURES
Table 1. Left Track Fails To Move Forward Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to drive BMPM forward
(TM 5-3895-385-10).
3. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, proceed to
next test.
4. Check fault screen for LEFT
1. If fault is found, proceed to WP
TRACK FORWARD EDC fault.
0150.
0215-1