TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
SPEED 2 COIL FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
Engine off (TM 5-3895-385-10)
WP 0314, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Speed 2 Coil Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for OUTPUT
1. If fault is found, turn keyless
MODULE OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10),
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction
proceed to next malfunction.
1. Disconnect main wiring harness
from W1 J6 from two speed
Vol 3, Figure 4).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.