Table 1. Spray Pump Fault Troubleshooting Procedures -- Continued
Table 1. Speed 2 Coil Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  1000    1001    1002    1003    1004  1005  1006    1007    1008    1009    1010  
img
. . . .
TM 5-3895-385-23-1
0205
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
SPEED 2 COIL FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0451, Vol 3
References
Equipment Conditions
WP 0182
Engine off (TM 5-3895-385-10)
WP 0314, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Speed 2 Coil Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Turn keyless engine switch to
screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for OUTPUT
1. If fault is found, turn keyless
MODULE OFFLINE fault.
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to WP 0182.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next malfunction
proceed to next malfunction.
2. Hydraulic solenoid malfunction.
1. Disconnect main wiring harness
from W1 J6 from two speed
hydraulic solenoid (WP 0451,
Vol 3, Figure 4).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
0205-1