Table 1. Spray Pump Malfunction Troubleshooting Procedures -- Continued
Table 1. Spray Pump Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  997    998    999    1000    1001  1002  1003    1004    1005    1006    1007  
img
. . . . .
TM 5-3895-385-23-1
0204
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
SPRAY PUMP FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0373, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0447, Vol 3
References
WP 0451, Vol 3
WP 0182
Equipment Conditions
WP 0277, Vol 2
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Spray Pump Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Screed Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check fault screen for OUTPUT
1. If fault is found, proceed to WP
MODULE OFFLINE fault.
0182.
2. If no fault is found, proceed to
next malfunction.
2. Relay malfunction.
1. Access spraydown pump relay
(WP 0277, Vol 2).
2. Turn keyless engine switch to
the AUX position (TM 5-3895-
385-10), but do not start engine.
3. Turn on spraydown pump using
operator pedestal keypad (TM 5-
3895-385-10).
0204-1