Table 1. Screed Controller Offline Fault Troubleshooting Procedures -- Continued
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  733    734    735    736    737  738  739    740    741    742    743  
img
. . .
TM 5-3895-385-23-1
0182
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
OUTPUT MODULE OFFLINE FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0386, Vol 2
Personnel Required
WP 0399, Vol 2
91L
WP 0443, Vol 3
Assistant
WP 0447, Vol 3
References
WP 0451, Vol 3
WP 0213
Equipment Conditions
WP 0277, Vol 2
Engine off (TM 5-3895-385-10)
WP 0373, Vol 2
TROUBLESHOOTING PROCEDURES
Table 1. Output Module Offline Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Output module (Electronic
1. Disconnect main wiring harness
Control Module (ECM)) has
W1 J3 and W1 J39 from output
damage or loose pin.
module ECM (WP 0451, Vol 3,
Figure 1).
2. Check output module ECM for
1. If output module ECM has
damage or loose pin.
damage or loose pin, replace
output module ECM (WP 0399,
Vol 2).
2. If no damage is found, proceed
to next test.
3. Check main wiring harness W1
1. If main wiring harness W1 J3 or
J3 and W1 J39 for damage or
W1 J39 has damage or loose
loose pin (WP 0451, Vol 3,
pin, repair or replace main
Figure 1).
wiring harness (WP 0373, Vol
2).
2. If no damage is found, proceed
to next malfunction.