MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
6. Main wiring harness has a short
Measure continuity (WP 0443, Vol
1. If continuity is present, replace
circuit.
3) between main wiring harness W1
main hydraulic manifold wiring
J4 Pin 19 and all other pins on the
harness (WP 0373, Vol 2).
main wiring harness W1 J4 (WP
0451, Vol 3, Figure 3).
2. If no continuity is present,
replace output module ECM (WP
0399, Vol 2).