Table 1. Screed Controller Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J2 Pin 4 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J2 (WP 0451, Vol 3,
Figure 2).
2. If no continuity is present,
proceed to next test.
1. If continuity is present, replace
0443, Vol 3) between main
main hydraulic manifold wiring
wiring harness W1 J2 Pin 5 and
harness (WP 0373, Vol 2).
all other pins on the main wiring
harness W1 J2 (WP 0451, Vol 3,
Figure 2).
2. If no continuity is present,
proceed to next malfunction.
15.Communication connector Y5
1. If continuity is present, proceed
has an open circuit.
0443, Vol 3) between
to next test.
communication connector Y5 P1
Pin A and Y5 P2 Pin A (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y5 (WP 0386, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y5 P1
Pin A and Y5 P3 Pin A (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y5 (WP 0386, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between
to next test.
communication connector Y5 P1
Pin B and Y5 P2 Pin B (WP
0451, Vol 3, Figure 49).
2. If no continuity is present,
replace communication
connector Y5 (WP 0386, Vol 2).
0181-9