Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  736    737    738    739    740  741  742    743    744    745    746  
img
.
TM 5-3895-385-23-1
0182
Table 1. Output Module Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Measure continuity (WP 0443,
1. If continuity is present, proceed
Vol 3) between main wiring
to next test.
harness W1 J3 Pin 10 and main
wiring harness W1 J4 Pin 26
(WP 0451, Vol 3, Figures 1 and
3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
6. Measure continuity (WP 0443,
1. If continuity is present, proceed
Vol 3) between main wiring
to next malfunction.
harness W1 J39 Pin 2 and main
wiring harness W1 J4 Pin 26
(WP 0451, Vol 3, Figures 1 and
3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
5. Main wiring harness has a short
Measure continuity (WP 0443, Vol
1. If continuity is present, replace
circuit.
3) between main wiring harness W1
main wiring harness (WP 0373,
J4 Pin 26 and all other pins on the
Vol 2).
main wiring harness W1 J4 (WP
0451, Vol 3, Figure 3).
2. If no continuity is present,
proceed to WP 0213.
6. Communication cable C1
Check communication cable C1 J1
1. If damage is found, replace
disconnected.
and J2 for proper connection and
communication cable C1 (WP
damage (WP 0451, Vol 3, Figure
0386, Vol 2).
51).
2. If no damage or loose
connection is found, proceed to
next malfunction.
3. If communication cable is found
disconnected, reconnect
communication cable properly.
0182-4