Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  710    711    712    713    714  715  716    717    718    719    720  
img
TM 5-3895-385-23-1
0180
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
2. If voltage reads below 22 VDC,
turn keyless engine switch to
the OFF position (TM 5-3895-
385-10), and replace main
wiring harness (WP 0373, Vol
2).
6. Measure voltage (WP 0443, Vol
1. If voltage reads a minimum of 22
3) between main wiring harness
VDC, turn keyless engine switch
W1 J2 Pin 1 and W1 J2 Pin 50
to the OFF position (TM 5-3895-
(WP 0451, Vol 3, Figure 2).
385-10), and proceed to
malfunction 6.
2. If voltage reads below 22 VDC,
turn keyless engine switch to
the OFF position (TM 5-3895-
385-10), and replace main
wiring harness (WP 0373, Vol
2).
3. Fuse blown.
1. Access fuse box (WP 0277, Vol
2).
2. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) across propel
to next malfunction.
controller fuse (WP 0447, Vol 3,
Figure 1).
2. If no continuity is present,
replace screed controller fuse
(WP 0277, Vol 2).
4. Main wiring harness has an
1. Measure for continuity (WP
1. If continuity is present, proceed
open circuit.
0443, Vol 3) between main
to next test.
wiring harness W1 J2 Pin 1 and
known good ground (WP 0451,
Vol 3, Figure 2).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
2. Disconnect main wiring harness
W1 J4 from fuse box (WP 0451,
Vol 3, Figure 3).
0180-3