TM 5-3895-385-23-1
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
BACK UP ALARM FAILS TO SOUND
INITIAL SETUP:
Test Equipment
References
Personnel Required
91L
WP 0371, Vol 2
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Back Up Alarm Fails To Sound Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to drive BMPM in
reverse (TM 5-3895-385-10).
3. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
2. If no fault is found, proceed to
next test.
4. Check fault screen for
1. If fault is found, proceed to WP
REVERSE ALARM fault.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and replace back up alarm (WP
0371, Vol 2).
END OF WORK PACKAGE