TM 5-3895-385-23-1
0180
Table 1. Propel Controller Offline Fault Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3. Measure for continuity (WP
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 50 and
main wiring harness W1 J4 Pin
24 (WP 0451, Vol 3, Figure 2
and 3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 49 and
main wiring harness W1 J4 Pin
24 (WP 0451, Vol 3, Figure 2
and 3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 48 and
main wiring harness W1 J4 Pin
24 (WP 0451, Vol 3, Figure 2
and 3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 47 and
main wiring harness W1 J4 Pin
24 (WP 0451, Vol 3, Figure 2
and 3).
2. If no continuity is present,
replace main wiring harness
(WP 0373, Vol 2).
1. If continuity is present, proceed
0443, Vol 3) between main
to next malfunction.
wiring harness W1 J2 Pin 2 and
main wiring harness W1 J4 Pin
24 (WP 0451, Vol 3, Figure 2
and 3).
0180-4