• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Right Auger Bypass Fault Troubleshooting Procedures -- Continued
Table 1. Vibrator Malfunction Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  698    699    700    701    702  703  704    705    706    707    708  
img
. . . . . . . . . .
TM 5-3895-385-23-1
0176
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
VIBRATOR MALFUNCTION
INITIAL SETUP:
Test Equipment
References -- Continued
Hydraulic test kit (WP 0440, Vol 3, Item 59)
WP 0257, Vol 2
Personnel Required
WP 0286, Vol 2
91L
WP 0293, Vol 2
Assistant
WP 0311, Vol 2
References
WP 0359, Vol 2
WP 0177
WP 0363, Vol 2
WP 0180
WP 0449, Vol 3
WP 0183
Equipment Conditions
WP 0188
Engine off (TM 5-3895-385-10)
WP 0239, Vol 2
Hydraulic oil cool (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Vibrator Malfunction Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. System fault indicated on fault
1. Start Bituminous Material Paving
screen.
Machine (BMPM) engine (TM 5-
3895-385-10).
2. Attempt to activate screed
vibrators (TM 5-3895-385-10).
3. Check fault screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, proceed to
next test.
4. Check fault screen for
1. If fault is found, proceed to WP
VIBRATOR RELAY fault.
0177.
2. If no fault is found, proceed to
next test.
0176-1