• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Right Auger Forward EDC Fault Troubleshooting Procedures -- Continued
Table 1. Left Auger Forward EDC Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  609    610    611    612    613  614  615    616    617    618    619  
img
. . . . .
TM 5-3895-385-23-1
0148
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT AUGER FORWARD EDC FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0319, Vol 2
Personnel Required
WP 0373, Vol 2
91L
WP 0399, Vol 2
Assistant
WP 0443, Vol 3
References
WP 0451, Vol 3
WP 0180
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Left Auger Forward EDC Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check faults screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next
malfunction.
2. Variable auger pump
1. Turn keyless engine switch to
malfunction.
the AUX position (TM 5-3895-
385-10), but do not start engine.
.
2. Locate W1 J27 at left variable
auger pump connector (WP
0373, Vol 2).
3. Attempt to turn left auger on at
maximum speed in the forward
direction in manual mode using
keypad (TM 5-3895-385-10).
0148-1