Table 1. Left Auger Forward EDC Fault Troubleshooting Procedures -- Continued
Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures -- Continued

Field Maintenance Manual For Bituminous Material Paving Machine - 1 Page Navigation
  612    613    614    615    616  617  618    619    620    621    622  
img
. . . . .
TM 5-3895-385-23-1
0149
FIELD MAINTENANCE
BITUMINOUS MATERIAL PAVING MACHINE (BMPM)
LEFT AUGER REVERSE EDC FAULT
INITIAL SETUP:
Test Equipment
References -- Continued
Multimeter (WP 0440, Vol 3, Item 37)
WP 0319, Vol 2
Personnel Required
WP 0373, Vol 2
91L
WP 0399, Vol 2
Assistant
WP 0443, Vol 3
References
WP 0451, Vol 3
WP 0180
Equipment Conditions
Engine off (TM 5-3895-385-10)
TROUBLESHOOTING PROCEDURES
Table 1. Left Auger Reverse EDC Fault Troubleshooting Procedures.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. Propel Controller Offline fault
1. Turn keyless engine switch to
indicated on fault screen.
the AUX position (TM 5-3895-
385-10), but do not start engine.
2. Check faults screen for PROPEL
1. If fault is found, proceed to WP
CONTROLLER OFFLINE fault.
0180.
2. If no fault is found, turn keyless
engine switch to the OFF
position (TM 5-3895-385-10),
and proceed to next
malfunction.
2. Variable auger pump
1. Turn keyless engine switch to
malfunction.
the AUX position (TM 5-3895-
385-10), but do not start engine.
.
2. Locate W1 J27 variable auger
pump left connector (WP 0373,
Vol 2).
0149-1