Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  174    175    176    177    178  179  180    181    182    183    184  
img
. . . . . . .
TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
There are many points on the BMPM where personnel could be injured by moving parts. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
5. Check for obstructed movement.
1. Remove any obstructions
around truck hitch arms.
2. If no obstructions are found,
proceed to next test.
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
as necessary (WP 0019).
2. Notify field maintenance if
problem persists.
61. Left conveyor fails to turn.
1. Check for Left Conveyor Speed
1. If no fault is found, proceed to
Coil fault indicated on fault
next test.
screen (WP 0004).
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
1. Ensure engine is on (WP 0006).
(WP 0006).
2. Ensure auger/conveyor bypass
is off.
3. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
(WP 0008).
fuse (WP 0008).
2. If blown fuse is not found,
proceed to next test.
0011-27