Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.

Technical Manual For Bituminous Material Paving Machine (Bmpm) Page Navigation
  152    153    154    155    156  157  158    159    160    161    162  
img
. . . . . . .
TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
WARNING
There are many points on the BMPM where personnel could be injured by moving parts. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
4. Check for obstructed movement.
1. Remove any obstructions
around and under screed.
2. If no obstructions are found,
proceed to next test.
5. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
as necessary (WP 0019).
2. Notify field maintenance if
problem persists.
5. Right screed extension fails to
1. Check for Right Slope Down
1. If no fault is found, proceed to
lower or raise slope.
fault or Right Slope Up fault
next test.
indicated on fault screen (WP
2. If fault is found, notify field
0004).
maintenance.
2. Check BMPM engine status.
Ensure engine is on (WP 0006).
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
(WP 0008).
fuse (WP 0008).
2. If blown fuse is not found,
proceed to next test.
0011-5