TM 5-3895-385-10
0011
Table 1. Bituminous Material Paving Machine (BMPM) Troubleshooting Procedures -- Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
4. Attempt operation with opposite
1. If opposite lights keypad
(left or right) lights keypad (WP
accomplishes operation, notify
field maintenance.
2. If opposite keypad does not
accomplish operation, turn
keyless engine switch to the
proceed to next test.
WARNING
There are many points on the BMPM where personnel could be injured by moving parts. Turn
BMPM off before performing maintenance. Care should be taken to avoid any pinch points when
performing maintenance. Failure to comply may cause injury or death to personnel.
5. Check for obstructed movement.
1. Remove any obstructions
around screed extension,
extension slide, and hydraulic
cylinders.
2. If no obstructions are found,
proceed to next test.
6. Check for proper hydraulic oil
1. Ensure hydraulic oil is at proper
level.
level and temperature, and fill
2. Notify field maintenance if
problem persists.
4. Left screed extension fails to
1. Check for Left Slope Down fault
1. If no fault is found, proceed to
lower or raise slope.
or Left Slope Up fault indicated
next test.
2. If fault is found, notify field
maintenance.
2. Check for proper BMPM setup
2. If conditions are met, proceed
to next test.
3. Check fuse box for blown fuse
1. If blown fuse is found, replace
2. If blown fuse is not found,
proceed to next test.