TM 5-3895-373-34
A.
REMOVE - Continued.
NOTE
Perform steps 3 and 4 if removing left
auger/ conveyor motor. Go to step 5
if
removing
right
auger/conveyor
motor.
3.
REMOVE INBOARD BATTERY.
Disconnect
batteries
prior
to
performing
maintenance
in
immediate battery area. Failure to
disconnect batteries may lead to
electrical shock or short circuit and
result in severe personnel injury or
damage to equipment.
a.
Unbuckle battery box holddown straps (13) and
remove battery box covers (14) from both
batteries.
b.
Remove panels (15).
When
disconnecting
batteries,
disconnect negative battery cable
before disconnecting positive battery
cable. Failure to disconnect batteries
in the proper sequence may lead to
electrical shock or short circuit and
result in severe personnel injury.
c.
Remove battery terminal caps (16).
d.
Remove battery nut (17) and negative battery
cable (18) from negative terminal of outboard
battery.
e.
Remove battery nut (17) and positive battery
cable (19) from positive terminal of inboard
battery.
f.
Remove battery nuts (20).
g.
Remove jumper battery cable (21) from positive
terminal of outboard battery and from negative
terminal of inboard battery.
h.
Remove inboard battery and battery box (22)
from paving machine.
GO TO NEXT PAGE
2-969