TM 5-3895-373-34
2.66.
REPLACE EXTENSION SCREED FRAME - Continued
D.
INSTALL - Continued.
Hydraulic fitting sealant can cause
eye damage or skin irritation. Wear
safety goggles/glasses when using.
Avoid contact with eyes or skin. If
sealant contacts eyes, flush eyes with
water and get immediate medical
attention.
Do not apply hydraulic fitting sealant
to leading threads of elbow. Seepage
of sealant into fuel system may clog
fuel nozzle.
i.
Apply hydraulic fitting sealant to threads of
elbow (67). Avoid getting sealant on leading
threads.
j.
Install and tighten screed burner fuel hose (66)
on elbow (67).
Electrical insulating varnish fumes
can be harmful if inhaled. Use only in
a
well
ventilated
area.
Avoid
prolonged exposure to fumes. If
personnel become dizzy or drowsy
during use, get immediate medical
attention.
k. Install lead wire (55) and terminal nut (53) on
terminal of glow plug (54). Apply electrical
insulating varnish to glow plug terminal.
GO TO NEXT PAGE
2-920