TM 5-3895-373-34
2.66.
REPLACE EXTENSION SCREED FRAME - Continued
D.
INSTALL - Continued.
e.
Remove one of two hex head cap screws (46)
along with lockwasher (47) from mounting
holes of center step support (48).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
f.
Apply thread locking compound (Item 13,
Appendix B) to the threads of hex head cap
screw (46).
g.
Install hex head cap screw (46). Do not tighten
at this time.
h.
Remove second hex head cap screw (46)
along with lockwasher (47).
i.
Apply thread locking compound (Item 13,
Appendix B) to threads of hex head cap screw
(46).
j.
Install second hex head cap screw (46).
k.
Tighten hex head cap screws (46) to 90 lb-ft
(122 Nm).
Do
not
apply
thread
locking
compound to hex head cap screws
(34). Damage to vibration mounts
(32) could occur during removal if
thread locking compound is applied.
NOTE
There are two vibration mounts on each
end of the right and left extension steps.
l.
Secure extension steps (33) to vibration
mounts (32) using hex head cap screws (34),
flat washers (36), and lockwashers (35). Do
not apply thread locking compound to hex
head cap screws. m. Tighten hex head cap
screws
(34)
snug.
m. Tighten hex head cap screws (34) snug.
GO TO NEXT PAGE
2-924