TM 5-3895-373-34
D.
INSTALL - Continued.
n.
Remove one of two hex nuts (38).
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
o.
Apply thread locking compound (Item 13,
Appendix B) to threads of installed hex head
cap screw (40).
p.
Install hex nut (38). Do not tighten at this time.
q.
Remove second hex nut (38).
r.
Apply thread locking compound (Item 13,
Appendix B) to threads of installed hex head
cap screw (40).
s.
Install hex nut (38). Tighten both hex nuts to 37
lb-ft (50 Nm).
t.
Remove cribbing from screed per TM 5-3895-
373-20.
u.
Retract extension screeds and lower screed
per TM 5-3895-373-10.
GO TO NEXT PAGE
2-925