TM 5-3895-373-34
2.49
REPAIR AUGER/CONVEYOR, VALVE AND CYLINDER, AND TOW POINT FLOW DIVIDERS - Continued.
D.
ASSEMBLE - Continued.
3.
INSTALL MOUNTING BRACKETS ON FLOW
DIVIDER.
WARNING
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
a.
Apply thread locking compound to hex head cap
screws (15).
b.
Position mounting brackets (17) on flow divider.
c.
Install hex head cap screws (15) through
mounting brackets (17) and flow divider.
d.
Install hex nuts (16) on hex head cap screws
(15). Tighten hex nuts to 15 lb-ft (20 Nm).
4.
IF NEW HEX HEAD CAP SCREWS HAVE
BEEN INSTALLED, USE A HACK SAW TO CUT
OFF THREADS OF HEX HEAD CAP SCREW
(18) THAT PROTRUDE BEYOND HEX NUT
(19).
GO TO NEXT PAGE
2-672