TM 5-3895-373-34
D.
ASSEMBLE Continued.
2.
INSTALL DOWEL PINS, CASES, AND END
PLATES ONTO FLOW DIVIDER.
WARNING
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to
the
skin,
eyes,
and
respiratory
system. Avoid prolonged exposure.
Eye protection and rubber gloves
must be worn when working with
hydraulic oil.
a.
Dip all metal flow divider parts being assembled
in clean hydraulic oil prior to assembly.
b.
Install dowel pins (24 and 25) into end plates
(20).
c.
Lubricate
preformed
packings
(23)
with
petrolatum. Install preformed packings into end
plate (20) and spacer plate (22).
d.
Assemble end plates (20), spacer plate (22), and
cases (21). Ensure preformed packings (23) are
seated in seal grooves.
WARNING
Thread locking compound can cause
eye
damage.
Wear
safety
goggles/glasses when using. Avoid
contact with eyes. If compound
contacts eyes, flush eyes with water
and get immediate medical attention.
e.
Apply thread locking compound to hex head cap
screws (18).
f.
Install hex head cap screws (18) through flow
divider.
g.
Install hex nuts (19) on hex head cap screw
threads. Tighten hex nuts to 15 lb-ft (20 Nm).
GO TO NEXT PAGE
2-671