TM 5-3895-373-34
2.49
REPAIR AUGER/CONVEYOR, VALVE AND CYLINDER, AND TOW POINT FLOW DIVIDERS - Continued.
D.
ASSEMBLE - Continued.
c.
Install hydraulic fittings onto auger/conveyor flow
divider.
WARNING
Pipe sealant can cause eye damage
or skin irritation. Wash after skin
contact. Wear safety goggles/glasses
when using. Avoid contact with eyes
or skin. If sealant contacts eyes,
flush
eyes
with
water
and
get
immediate medical attention.
(1)
Apply pipe sealant to pipe thread end
elbow (3) and straight adapters (1).
(2)
Install elbow (3) onto auger/conveyor
flow divider (2), with elbow pointing away
from flow divider.
(3)
Install straight adapters (1).
NOTE
FOLLOW-ON-TASK: Install flow divider repaired per paragraph 2.55.
END OF TASK
2-674