TM 5-3895-373-34
C.
INSTALL - Continued.
5.
INSTALL CHECK VALVE.
Hydraulic
oil
can
be
moderately
flammable and can be an irritant to the
skin, eyes, and respiratory system.
Avoid prolonged exposure. Eye
protection and rubber gloves must be
worn when working with hydraulic oil.
a.
Dip check valve (13 or 14) into clean bath of
hydraulic oil.
b.
Install check valve (13 or 14). Using crowfoot
wrench (Item 124, Appendix D) and socket
wrench adapter, tighten check valve to 30 Ib-ft
(40 Nm).
6.
INSTALL SAFETY RELIEF VALVE.
a. Dip safety relief valve (12) into clean bath of
hydraulic oil.
b. Install safety relief valve (12). Using crowfoot
wrench (Item 124, Appendix D) and socket
wrench adapter, tighten relief valve to 30 lb-ft (4
Nm).
GO TO NEXT PAGE
2-617